PRODUCTS

  • Microphone
  • Measurement condenser microphone

Measurement condenser microphone
TYPE 7023
(TYPE 1)

702223

About the product

There are two type of ACO microphones : preamplifier integrated microphone and condenser microphone.
Preamplifier integrated microphone compatible with IEPE can be connected directly to FFT analyzer or other analyzers, enabling to measure with highly accurate resolution at low costs.
Long-term stability realized by accelerated aging process under 360℃ enables to use under 100℃ or higher.
Condenser microphone is to be used for measurements of sound presser level with high resolution over wide frequency range.
Varieties of microphone diaphragm diameter 1,1/2, 1/4, 1/6, 1/8 inch and corresponding frequency characteristics would best support measurements of various purposes.
The diameters and electroacoustic characteristics of these measurement microphones comply with the international standard IEC 61094-4:1995.
It also complies with the microphone specifications required by IEC 61672, which is an important standard for measurement systems such as Class 1/ Class 2 sound level meters.
TYPE 1 and TYPE 2 indicates compliance with IEC 61672 Class 1 and Class 2, respectively.

Product Specifications

Wide frequency range
Wide range of measurement from low-frequency to ultrasonic frequency(1Hz~200kHz) is possible.

Wide dynamic range
Measurement of high sound pressure level up to 170dB is possible.

Preamplifier integrated microphone
It is also possible to connect directly to analyzer by using BNC cable.

For high sensitivity requirement
If high sensitivity is required, Type 7146/4152N20 offers 500 mV/Pa and it can measure from low sound pressure level..
It can be directly connected to equipment such as FFT Analyzer. and is easy to use.
meas_mic_freq
TypeTYPE 7023(TYPE1)
Appearance
※When the image is clicked,
it is displayed by the zoon.
type7022_7023
Frequency Response CharacteristicPressure-Field
Nominal Diameter1 inch
Release voltage-28dB (39.8mV/Pa)
Polarization voltage200V
Frequency Characteristics10Hz~10kHz
Maximum sound pressure level146dB
Self-noise level13dB(A)
Temperature coefficient0.007dB/℃ or less
Preamplifier TypeTYPE4022 (with 1 inch adapter)
Operating Temperature・
Range of Humidity
-10℃~+50℃・90%RH (no condensation)
Storage Temperature・
Range of Humidity
40% or less (at room temperature)
Outline sizeΦ23.77×19
Weight27.6g
image61132_2

Download